The American Water Works Association (AWWA) has released the 2021 edition of AWWA D100, which includes significant changes to the design, construction, and inspection of welded steel tanks for water storage. These changes affect engineers, inspectors, and compliance professionals involved in the construction and maintenance of water storage tanks. The updates are crucial for ensuring the safety and reliability of water storage systems.
Quick Summary
- Revised seismic design requirements
- Updated welding and inspection procedures
- New requirements for tank foundation and anchorage
- Improved corrosion protection measures
Why This Matters
The updates in AWWA D100-21 have significant implications for the design, construction, and maintenance of water storage tanks. The revised seismic design requirements, for example, will impact the structural integrity of tanks in earthquake-prone areas. The updated welding and inspection procedures will affect the quality and safety of tank construction. Compliance with these changes is essential for ensuring the reliability and safety of water storage systems.
Side-by-Side Comparison
| Topic | Previous Edition | Current Edition | Impact |
|---|---|---|---|
| Seismic Design | Based on 1994 UBC | Based on ASCE 7-16 | Increased emphasis on seismic resilience |
| Welding Procedures | Based on AWS D1.1-2010 | Based on AWS D1.1-2015 | Improved weld quality and inspection |
| Tank Foundation | No specific requirements | Requires designed foundation and anchorage | Enhanced tank stability and safety |
| Corrosion Protection | Coating requirements only | Includes cathodic protection and coating requirements | Improved corrosion resistance and longevity |
| Inspection Requirements | Visual inspection only | Includes non-destructive testing (NDT) and visual inspection | Enhanced inspection accuracy and reliability |
What Changed
- Revised seismic design requirements
- Updated welding and inspection procedures
- New requirements for tank foundation and anchorage
- Improved corrosion protection measures
What Stayed the Same
- Material specifications
- Tank design and construction requirements
- Testing and commissioning procedures
What This Means in Practice
- Engineers and designers must update their designs to reflect the revised seismic requirements
- Contractors and fabricators must adhere to the updated welding and inspection procedures
- Inspectors must be trained on the new inspection requirements
Do You Need the Latest Edition?
- You need the latest edition if you are involved in the design, construction, or inspection of water storage tanks
- You may still use the previous edition if you have already completed the design and construction of your tank, but you must ensure that it meets the current regulatory requirements
- Compliance with the latest edition is mandatory for all new tank constructions and inspections
Scope and Applicability
The AWWA D100-21 standard applies to the design, construction, and inspection of welded steel tanks for water storage. The standard covers the requirements for tank design, materials, welding, inspection, and testing.
Key Changes
The 2021 edition of AWWA D100 includes several key changes, including revised seismic design requirements, updated welding and inspection procedures, new requirements for tank foundation and anchorage, and improved corrosion protection measures.
Technical Requirements
The standard includes technical requirements for tank design, materials, welding, inspection, and testing. The requirements are based on industry best practices and are intended to ensure the safety and reliability of water storage tanks.
Design Implications
The revised seismic design requirements will impact the structural integrity of tanks in earthquake-prone areas. The updated welding and inspection procedures will affect the quality and safety of tank construction. The new requirements for tank foundation and anchorage will enhance tank stability and safety.
Compliance Considerations
Compliance with the AWWA D100-21 standard is mandatory for all new tank constructions and inspections. Engineers, designers, contractors, and inspectors must ensure that they are familiar with the revised requirements and adhere to them during the design, construction, and inspection process.
Where to Get This Standard
The AWWA D100-21 standard is published by the American Water Works Association (AWWA) and is available from retailers including Publications Office.
- The AWWA D100-21 standard includes revised seismic design requirements
- The standard updates welding and inspection procedures
- New requirements for tank foundation and anchorage are included
- Improved corrosion protection measures are specified
- Compliance with the standard is mandatory for all new tank constructions and inspections
- Engineers, designers, contractors, and inspectors must ensure that they are familiar with the revised requirements
Q: What are the key changes in the AWWA D100-21 standard?
A: The key changes include revised seismic design requirements, updated welding and inspection procedures, new requirements for tank foundation and anchorage, and improved corrosion protection measures.
Q: Who must comply with the AWWA D100-21 standard?
A: Compliance with the standard is mandatory for all new tank constructions and inspections. Engineers, designers, contractors, and inspectors must ensure that they are familiar with the revised requirements.
Q: What are the implications of the revised seismic design requirements?
A: The revised seismic design requirements will impact the structural integrity of tanks in earthquake-prone areas. Engineers and designers must update their designs to reflect the revised requirements.
Q: What are the updated welding and inspection procedures?
A: The updated welding and inspection procedures are based on AWS D1.1-2015 and include non-destructive testing (NDT) and visual inspection.
Q: What are the new requirements for tank foundation and anchorage?
A: The new requirements for tank foundation and anchorage include designed foundation and anchorage to enhance tank stability and safety.
Q: Do I need the latest edition of the standard?
A: You need the latest edition if you are involved in the design, construction, or inspection of water storage tanks. You may still use the previous edition if you have already completed the design and construction of your tank, but you must ensure that it meets the current regulatory requirements.
Q: Where can I purchase the AWWA D100-21 standard?
A: The AWWA D100-21 standard is published by the American Water Works Association (AWWA) and is available from retailers including Publications Office.
Q: What is the role of the Authority Having Jurisdiction (AHJ) in enforcing the standard?
A: The AHJ is responsible for enforcing the standard and ensuring that all water storage tanks are designed, constructed, and inspected in accordance with the AWWA D100-21 standard.
๐ AWWA D100-21 Welded Steel Tanks for Water Storage
American Water Works Association (AWWA) ยท 2021 โ Instant PDF delivery
Access This Publication โ